3nh New Vertical Type Haze Meter with ASTM D1003 and ISO 13468 standard

July 2, 2021
Latest company news about 3nh New Vertical Type Haze Meter with ASTM D1003 and ISO 13468 standard

3nh New Vertical Type Haze Meter

latest company news about 3nh New Vertical Type Haze Meter with ASTM D1003 and ISO 13468 standard  0

Product model YH1600 Haze Meter YH1200 Haze Meter YH1100 Haze Meter YH1000 Haze Meter
Geometry Transmittance: 0/D (parallel illumination, diffuse receiving);Conform to the standards: ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, GB/T 3978, ASTM E308, JIS K7105, JIS K7361, JIS K 7136 Transmittance:0/D (Parallel light illumination, diffuse viewing); Conform to the standards:ASTM D1003/1044,ISO 13468,ISO 14782,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 Transmittance:0/D(Parallel light illumination, diffuse viewing);Conform to the standards:ASTM D1003/1044, ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 Transmittance:0/D(Parallel light illumination, diffuse viewing);Conform to the standards:ASTM D1003/1044,GB/T 2410,JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136
Characteristic The instrument can easily realize ASTM D1003 non-compensated method, ISO 13468 compensation method, full transmittance, haze test. The instrument can accurately collect the transmittance curve of the transmitted sample, and can accurately output various chroma data of the transmitted sample. High hardware configuration, open measurement area, vertical, horizontal testing. It is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects. The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance,haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection.
Integrating sphere size Φ 154 mm Φ154mm Φ154mm Φ154mm
Light source 400 ~ 700 nm combined LED light source (wavelength scalable customized) 400nm to 700nm, combined LED light 400nm to 700nm, combined LED light 400nm to 700nm, combined LED light
Spectrophotometric Mode Concave grating / / /
Sensor 256 pixel dual array CMOS image sensor The PD array detector satisfies CIE V(λ)2 degree visual response The PD array detector, satisfies CIE V(λ)2 degree visual response The PD array detector, satisfies CIE V(λ)2 degree visual response
Wavelength range 400 ~ 700 nm (wavelength scalable customization) / / /
Wavelength interval 10 nm / / /
Half bandwidth 10 nm / / /
Measurement Range 0-100% 0~100% 0~100% 0~100%
Measuring aperture Φ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture) Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture) Φ20mm/Φ15mm/Φ8mm/Φ4mm(Select a single aperture)
Sample size Thickness less than 170 mm Thickness <170mm Thickness <170mm Thickness<170mm
Color space CIE LAB, XYZ, Yxy, LCh, s-RGB, βxy / / /
Chromatic formula ΔEab, ΔE94, ΔEcmc (2:1), ΔEcmc (1:1), ΔE00 / / /
Other chromaticity index Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM), WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), Absorbance, Cobalt Platinum Index, Gardner Index Haze(ASTM D1003/1044,ISO13468),Transmittance T(ISO),Transmittance T(ASTM) Haze(ASTM D1003/1044),Transmittance T(ASTM) Haze(ASTM D1003/1044),Transmittance T(ASTM)
Observer angle 2 °/10 °
Light source D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 D65,A,C D65,A,C D65,A,C
Display Data Spectrogram, sample chroma value, color difference/graph, color graph, color simulation, pass/fail result PASS/FAIL Result PASS/FAIL Result PASS/FAIL Result
Measurement time About 1.5s About1.5s About1.5s About1.5s
Resolution 0.01 unit 0.01unit 0.01unit 0.01unit
Repeatability Φ20 mm aperture, less than 0.08 (after instrument preheating and correction, test the standard nebulizer with the nebulization of about 40 at an interval of 5s for 30 times of standard deviation) Φ20mm,within 0.1 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.) Φ20mm,within 0.1(After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.) Φ20mm,within 0.15 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 40 for 30 times were taken at intervals of 5s.)
Inter-instrument Error Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5s) Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) Φ20mm,with 0.4(After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.)
Dimensions Length * Width * Height = 290*211*511 mm L*W*H=290X211X511mm L*W*H=290X211X511mm L*W*H=290X211X511mm
Weight Approx. 7.6 kg About7.6kg About7.6kg About7.6kg
Power supply 24 V DC, supplied by 3A power adapter AC 24V, 3A Power adapter power supply AC 24V, 3A Power adapter power supply AC 24V, 3A Power adapter power supply
Illuminant Life Span > 3 million measurements in 5 years 5 years, more than 3 million times measurements 5 years, more than 3 million times measurements 5 years, more than 3 million times measurements
Display TFT True Color 7 inch, Capacitive Touchscreen 7-inch TFT color LCD, Capacitive Touch Screen 7-inch TFT color LCD, Capacitive Touch Screen 7-inch TFT color LCD, Capacitive Touch Screen
Interface USB, Print Serial,Bluetooth USB, Print serial port USB, Print serial port USB, Print serial port
Data Storage 5,000 samples, 20,000 samples Standard 1000 pcs,sample 20000 pcs Standard 1000 pcs,sample 20000 pcs Standard 1000 pcs,sample 10000 pcs
Language Simplified Chinese, Traditional Chinese, English Simplified Chinese,Traditional Chinese,English Simplified Chinese,Traditional Chinese,English Simplified Chinese,Traditional Chinese,English
Operating Temperature 0 to 40 ° C (32 to 104 ° F) 0~40℃(32~104°F) 0~40℃(32~104°F) 0~40℃(32~104°F)
Storage Temperature - 20 – 50 ° C (-4 – 122 ° F) -20~50℃(-4~122°F) -20~50℃(-4~122°F) -20~50℃(-4~122°F)
Standard Accessories Power adapter, user manual, quality management software (download), USB cable, 0% calibration box, measuring aperture Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture. Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture. Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture.
Optional Accessories Micro printer, Test Fixture, Standard Haze Sheet, Footswitch Micro-printer,Test fixture, standard haze sheet, foot switch Micro-printer,Test fixture, standard haze sheet, foot switch Micro-printer,Test fixture, standard haze sheet, foot switch
Notes: Subject to change without notice The specifications are subject to change without notice. The specifications are subject to change without notice. The specifications are subject to change without notice.